Red brick two-story house with a brick chimney, shuttered windows and a small porch

Gas Fireplace Repair in Burbank, Including the Venting

A pilot that will not stay lit, a burner that will not light or soot on the glass.

Describe the Problem

Camera Scan of the Flue
Stills With Every Report
Written Quote Before Work
Liners Sized to the Appliance
Based in Burbank
Camera Scan of the Flue
Stills With Every Report
Written Quote Before Work
Liners Sized to the Appliance
Based in Burbank

What We Check and Do

A gas fireplace that will not light or keeps shutting off usually has one failed part: the thermocouple, thermopile, valve, igniter or control board. We test each in turn with a meter. We also check the venting, because a blocked or undersized flue can trip a safety switch and pass for a parts fault. The repair is quoted in writing once the cause is found and shown to you.

Thermocouple and thermopile metered
Valve and igniter tested
Control board faults traced
Vent checked for blockage
Gas leak test after the fix

Pilots, Thermocouples and the Usual Faults

Most gas fireplace faults fall into a short list. The pilot will not light, which can be a gas supply issue, a blocked pilot orifice or a failed igniter. The pilot catches, then dies as soon as the knob is released, which usually points at the thermocouple or thermopile, the small sensors that prove the flame is there. The pilot stays lit but the burner will not come on, which can be the thermopile, the valve, a wall switch or a remote receiver with a dead battery. The flame is lazy, yellow and leaves soot, which points at air supply, log placement or a venting problem. We test each part in order with a meter, rather than swapping parts until something works. The diagnosis goes into the quote with the part and its price, so you know what you are paying for.

A gas fireplace that shuts itself off after a few minutes is often doing exactly what it should. Many units carry a safety sensor that turns the gas off when exhaust is spilling back into the room, and that usually means the vent is blocked or the liner has failed. In those cases the repair is not on the unit at all. We check the vent termination, the liner and the old flue around it before we touch the valve, and if a camera run is needed to see the liner, we say so and explain why. In Burbank, birds and wasps nesting in vent caps are a common cause in spring, and a damper knocked shut on a vented log set is another. Clearing the vent clears the shutoff.

Repair or Replace an Older Gas Unit

Gas fireplaces and inserts have long lives, but parts get harder to find as models age. When a valve or control board fails on an older unit, the part can be expensive or no longer made. In that case the written quote shows both paths: the repair, if a part can be found, and a replacement, with the price for a new gas insert at $2,650 to $5,300 installed or, if you want the fire somewhere else in the room, $4,250 to $8,500 for a direct-vent unit vented straight out. We also note what else a replacement would change. A new insert usually needs a new liner sized for it, and the old one comes out. A new direct-vent unit may need a new wall or roof termination. Having both options on one page lets you decide without a second visit.

Gas work in Pasadena, Glendale and Canoga Park houses often runs into an older gas line, a missing shutoff valve near the appliance or a unit installed without the clearances its label asks for. We note those things when we see them, because they matter for safety and for a buyer's inspection if the house is sold. Some fixes, such as adding a shutoff valve, are small. Others, such as rerouting a gas line, may need a permit, and the quote says so. If you are calling because a buyer's inspector flagged the fireplace, tell us what the report said; we can answer that item directly. Send the make and model from the label inside the lower panel if you can find it. A short clip of what the unit does when it fails helps even more.

  • Scan First
  • Stills Marked
  • Posted Prices
  • Sized to the Appliance
Call (747) 224-8947